.03 DA / .03 DA-2T / .03 DA-2C Deaerators
|
|
Atmospheric deaerators are recommended for low-pressure boiler applications. The standard .03 design removes dissolved oxygen to a maximum level of .03 cubic centimeters per liter of feed water. The amount of hot condensate returns influences which design is most appropriate for applications. A single-compartment .03 DA unit is typically used on systems having 80% or more make-up water. Two-compartment design (.03 DA-2C) or two-tank design (.03 DA-2T) that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate.
Two-compartment deaerators also recommended:
- where floor space may not be sufficient for a two-tank design
- when a complete, factory-packaged unit is preferred instead of field wiring and piping of a free-standing surge tank and deaerator
The two-compartment design enables the flash steam that escapes the deaeration compartment to be recovered by the direct contact vent condensor in the accumulator compartment. This method allows minimal vent loss. Standard deaerators receivers available in black steel. On two-tank designs the free-standing surge tank can be plasite-lined or made 300 series stainless steel; on two-chamber designs, the surge tank can be plasite-line or the complete tank made 300 series stainless steel. Unit can built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps typically bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Higher temperature seals and special faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerators equipped with direction steam injection assembly with stainless steel preheat tube; assembly includes temperature regulator that can be either pneumatic controlled or self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .03 DA
Get product literature for .03 DA-2T
Get product literature for .03 DA-2C
|
|
|
.03 DA-CI / .03 DA-CI-2T Deaerators
|
|
Atmospheric deaerators are recommended for low-pressure boilers. Unit design similar to the .03 DA or .03 DA-2T except that receiver material is close-grained with a standard 20-year warranty against corrosion failure for maximum corrosion resistance. Standard receiver sizes available up to 500 gallons using a single tank; larger capacities possible with customized designs using multiple receivers.
Go to top • Glossary
|
Get product literature for .03 DA-CI
Get product literature for .03 DA-CI-2T
|
|
|
.005 DA-STV / .005 DA-STV-2T Deaerators
|
|
Atmospheric deaerators are recommended for high-pressure boiler applications. Vertical orientation makes model ideal for applications where available floor space is limited. The atmospheric design allows for gravity returns and generally produces less steam loss under partial load conditions than pressurized deaerators. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Atmospheric deaerators provides unrestricted venting of the non-condensing gases.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design is typically used on systems having 80% or more make-up water. A two-tank design (DA-STV-2T) that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate. Standard deaerators receivers available in black steel. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit can be built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depend upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Special seal faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerators equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes temperature regulator that can be either pneumatic controlled or self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-STV
Get product literature for .005 DA-STV-2T
|
|
|
.005 DA-STVP / .005 DA-STVP-2T Deaerators
|
|
Pressurized deaerators are recommended for high-pressure boiler applications or where available floor space is limited since the design uses a vertical orientation. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-STVP) is typically used on systems having 80% or more make-up water. A two-tank design (DA-STVP-2T) is typically used on systems having more than 20% return hot condensate. Standard deaerator receivers made of black steel and also ASME code stamped. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit can built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Typically, pumps are bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Special faces on seals available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes pressure regulator that is self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-STVP
Get product literature for .005 DA-STVP-2T
|
|
|
.005 DA-SCP / .005 DA-SCP-2T Deaerators
|
|
The affordable, small capacity (from 20 BHP), pressurized deaerator is recommended for high-pressure applications where customers typically could not afford a deaerator and settled for a boiler feed unit with preheat. Unit equipped with internal spray-tray design. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Unit designed so that undeaerated water only comes in contact with stainless steel to prolong life of unit.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-SCP) is typically used on systems having 80% or more make-up water. A two-tank design (DA-SCP-2T) that includes a stand-alone surge tank is typically used on systems having more than 20% return hot condensate. Standard deaerator receiver available in black steel and ASME code stamped with an extra corrosion allowance of 1/16" beyond ASME code requirements added. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit can be built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Pumps can be mounted in either a vertical or horizontal orientation. Deaerators equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes pressure regulator that is self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-SCP
Get product literature for .005 DA-SCP-2T
|
|
|
.005 DA-IST / .005 DA-IST-2T Deaerators
|
|
Atmospheric deaerators are recommended for high-pressure boiler applications. Unit equipped with internal spray-tray design. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. The atmospheric deaerator design provides unrestricted venting of the non-condensing gases, allows for gravity returns, and generally produces less steam loss under partial load conditions than a pressurized deaerator. Unit designed so that undeaerated water only comes in contact with stainless steel to prolong life of unit.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-IST) is typically used on systems having 80% or more make-up water. A two-tank design (DA-IST-2T) that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate. Standard deaerator receivers available in black steel. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit can be built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Higher temperature seals and special faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerators equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes temperature regulator that can be either pneumatic controlled or self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-IST
Get product literature for .005 DA-IST-2T
|
|
|
.005 DA-ISTP / .005 DA-ISTP-2T Deaerators
|
|
Pressurized deaerators are recommended for high-pressure boiler applications. Unit equipped with internal spray-tray design. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Unit designed so that undeaerated water only comes in contact with stainless steel to prolong life of unit.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-ISTP) is typically used on systems having 80% or more make-up water. A two-tank design (DA-ISTP-2T)that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate. Standard deaerator receiver available in black steel and ASME code stamped with an extra corrosion allowance of 1/16" beyond ASME code requirements added. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit can be built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Special faces available on seals upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes pressure regulator that is self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-ISTP
Get product literature for .005 DA-ISTP-2T
|
|
|
.005 DA-ST / .005 DA-ST-2T Deaerators
|
|
Atmospheric deaerators are recommended for high-pressure boiler applications. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. The atmospheric deaerator design provides unrestricted venting of the non-condensing gases, allows for gravity returns and generally produces less steam loss under partial load conditions than a pressurized deaerator. Unit designed so that undeaerated water only comes in contact with stainless steel to prolong life of unit.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-ST) is typically used on systems having 80% or more make-up water. A two-tank design (DA-ST-2T) that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate. Standard deaerator receivers available in black steel. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit designed with stainless steel trays in external black steel dome with removable trays in the dome. Unit can built to handle a wide range of flows and pressures; receiver can be customized terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Special faces on seals available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes temperature regulator that can be either pneumatic or self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-ST
Get product literature for .005 DA-ST-2T
|
|
|
.005 DA-STP / .005 DA-STP-2T Deaerators
|
|
Pressurized deaerators are recommended for high-pressure boiler applications. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Unit designed so that undeaerated water only comes in contact with stainless steel to prolong life of unit.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-STP) is typically used on systems having 80% or more make-up water. A two-tank design (DA-STP-2T) that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate. Standard deaerator receiver available in black steel and ASME code stamped with an extra corrosion allowance of 1/16" beyond ASME code requirements added. Unit designed with stainless steel trays in external black steel dome that is removable from the receiver; with removable trays in the dome. For two-tank designs, the surge tank can be either plasite-lined or made 300 series stainless steel. Unit can built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Options for stress relieving and radiography testing of receiver available upon request. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Higher temperature seals and special faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes pressure regulator that is self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-STP
Get product literature for .005 DA-STP-2T
|
|
|
.005 DA-CI / .005 DA-CI-2T Deaerators
|
|
Atmospheric deaerators are recommended for high-pressure boiler applications. Designed with stainless steel trays in external black steel dome that is removable from the receiver. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. The atmospheric deaerator provides unrestricted venting of the non-condensing gases, allows for gravity returns and generally produces less steam loss under partial load conditions than a pressurized deaerator. Unit designed so that undeaerated water only comes in contact with stainless steel to prolong life of unit.
The amount of hot condensate returns influences which design is most appropriate for applications. A single-tank design (DA-CI) is typically used on systems having 80% or more make-up water. A two-tank design (DA-CI-2T) that includes a standalone surge tank is typically used on systems having more than 20% return hot condensate. A close-grained, cast iron receiver is provided with a standard 20-year warranty against corrosion failure for maximum corrosion resistance. Standard receiver sizes available up to 500 gallons using a single tank; larger capacities possible with customized designs using multiple receivers. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Higher temperature seals and special faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direct steam injection assembly with stainless steel preheat tube; assembly includes temperature regulator that can be either pneumatic or self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-CI
Get product literature for .005 DA-CI-2T
|
|
|
.005 DA-2C Deaerators
|
|
Atmospheric deaerators are recommended for high-pressure boiler applications. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Two-compartment design is typically used:
- on systems having more than 20% return hot condensate
- where floor space may not be sufficient for a two-tank design
- when a complete, factory-packaged unit is preferred instead of field wiring and piping of freestanding surge tank and deaerator
The two-compartment design enables the flash steam that escapes the deaeration compartment to be recovered by the direct contact vent condensor in the accumulator compartment. This method allows minimal vent loss. Standard deaerator receivers available in black steel. The complete unit can be plasite-lined or made of 300 series stainless steel. Unit can built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Higher temperature seals and special faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Unit equipped with direction steam injection assembly with stainless steel preheat tube; assembly includes temperature regulator that can be either pneumatic controlled or self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-2C
|
|
|
.005-DA-STP-2C Deaerators
|
|
Pressurized deaerators are recommended for high-pressure boiler applications. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Two-compartment design is typically used:
- on systems having more than 20% return hot condensate
- where floor space may not be sufficient for a two-tank design
- when a complete, factory-packaged unit is preferred instead of field wiring and piping of freestanding surge tank and deaerator
Standard deaerator receiver available in black steel and ASME code stamped with an extra corrosion allowance of 1/16" beyond ASME code requirements added. Unit designed with trays removable from the dome. The surge chamber can be plasite-lined or the complete tank made 300 series stainless steel. Unit can built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Options for stress relieving and radiography testing of receiver available upon request. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps typically bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Higher temperature seals and special faces available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direction steam injection assembly with stainless steel preheat tube; assembly includes pressure regulator that is self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005-DA-STP-2C
|
|
|
.005 DA-ISTP-2C Deaerators
|
|
Pressurized deaerators are recommended for high-pressure boiler applications. Design has trays internal to receiver. The standard .005 design removes dissolved oxygen to a maximum level of .005 cubic centimeters per liter of feed water. Two-compartment design is typically used:
- on systems having more than 20% return hot condensate
- where floor space may not be sufficient for a two-tank design
- when a complete, factory-packaged unit is preferred instead of field wiring and piping of freestanding surge tank and deaerator
Standard deaerator receiver available in black steel and ASME code stamped with an extra corrosion allowance of 1/16" beyond ASME code requirements added. The surge chamber can be plasite-lined or the complete tank made 300 series stainless steel. Unit can built to handle a wide range of flows and pressures; receiver can be customized in terms of diameter, length and height to meet job specific requirements. Options for stress relieving and radiography testing of receiver available upon request. Number of pumps on unit depends upon number of boilers to be supported and stand-by specifications. Pump motors can be either 1750 RPM or 3500 RPM, single or three phase. Unit equipped with single stage or multi-stage pumps depending upon operating conditions. Pumps bronze-fitted with industry standard motors and mechanical seals rated for temperatures up to 300°F. Special faces on seals available upon request. Pumps can be mounted in either a vertical or horizontal orientation. Deaerator equipped with direction steam injection assembly with stainless steel preheat tube; assembly includes pressure regulator that is self-contained. Other accessories include but not limited to gauge glass assembly thermometer, inlet strainer, butterfly isolation valve, low-water cut-off or alarm switch, electrical control panels and tank insulation.
Go to top • Glossary
|
Get product literature for .005 DA-ISTP-2C
|