Shipco® Pumps Welcome to Shipco® Pumps
# July 3, 2008   PrintPrint this page
Shipco® Pumps (Printer version) - Thursday, July 03, 2008 7:33:27 PM

Vacuum Units

#Show: [All units]Only Cast IronOnly Steel

Go directly to type...
  LRV *  
  LRV-S *  
  BVC
BVMC
 
  SHVC
SHVM
 
  BV  
* = Defender Series

Navigator

Vacuum Units Overview

Designed to remove air and lift condensate in the condensate recovery portion of your steam heating system. Receiver typically has two compartments—one to collect hot condensate and one to produce the vacuum. Tank material can be close-grained cast iron or black steel. Thicker black steel or 300 series stainless steel is option on some models for increased corrosion resistance. Both simplex and duplex configurations are available with/without mounted, pre-wired control panels.

Benefits

  • Lower boiler operating costs by enabling boiler to run at a lower operating pressure and still get a pressure differential across traps in steam system.
  • Achieve substantial energy savings by collecting the already heated condensate and returning it faster to the boiler thereby lowering the consumption of fuel needed to heat additional cold make-up water.
  • Lower operating costs by reusing hot condensate already chemically treated thereby reducing the consumption of additional chemicals needed to treat fresh make-up water.
LRV Vacuum Pump (Defender Series)

LRV Low Return Vacuum heating unit with a combination air and water pump that performs both the condensate and vacuum pumping functions. Multi-jet design proven to be effective and reliable means for removing air and lifting hot condensate in the return system. A standard cast iron receiver is provided with a standard 20-year warranty against corrosion failure for years of service. Standard unit designed for applications with low returns and system capacities ranging up from 2,500 square feet EDR; air pumps range up from 3 cubic feet per minute (cfm) at 5½" HG at 160°F. Unit completely packaged, including electrical controls.

Units are available in either simplex or duplex configuration with either 1750 RPM or 3500 RPM motors in either single or three phase. Pumps are flange mounted to the receiver and equipped with industry standard motors. Pumps bronze-fitted with removable bronze wearing ring and with mechanical seals rated for temperatures up to 250°F. Higher temperature seals and special faces available upon request.

^Go to top#Glossary

#Get product literature for LRV
LRV-S Vacuum Pump (Defender Series)

LRV-S Low Return Vacuum heating unit with a combination air and water pump that performs both the condensate and vacuum pumping functions. Multi-jet design proven to be effective and reliable means for removing air and lifting hot condensate in the return system. A standard steel receiver is provided with for years of service. Standard unit designed for applications with low returns and system capacities ranging up from 2,500 square feet EDR; air pumps range up from 3 cubic feet per minute (cfm) at 5½" HG at 160°F. Unit completely packaged, including electrical controls.

Units are available in either simplex or duplex configuration with either 1750 RPM or 3500 RPM motors in either single or three phase. Pumps are flange mounted to the receiver and equipped with industry standard motors. Pumps bronze-fitted with removable bronze wearing ring and with mechanical seals rated for temperatures up to 250°F. Higher temperature seals and special faces available upon request.

^Go to top#Glossary

#Get product literature for LRV-S
BVC / BVMC Vacuum Pumps

BVC / BVMC Big Vacuum and Condensate unit with independent air and water pumps. Multi-jet design proven effective and reliable for removing air and lifting hot condensate in the return system. A standard cast iron receiver is provided with a standard 20-year warranty against corrosion failure for years of service. The vacuum tank (or hurling chamber) is either heavy gauge, black steel or cast iron depending upon sizing. Standard unit designed for applications with system capacities ranging up from 1,000 square feet EDR; air pumps range up from 5.8 cubic feet per minute (cfm) at 5½" HG at 160°F. Unit completely packaged, including electrical controls.

Units are available in either simplex or duplex configuration with either 1750 RPM or 3500 RPM motors in either single or three phase. Pumps are flange mounted to the receiver and equipped with industry standard motors. Pumps bronze-fitted with removable bronze wearing ring and with mechanical seals rated for temperatures up to 250°F. Higher temperature seals and special faces available upon request.

Air and water pumps can be sized separate for customized applications that standard unit configurations can not meet.

Type BVMC is the boiler feed unit version of the BVC. An electrical solenoid make-up water valve with float switch control is standard. A low water cut-off switch is furnished to prevent pumps from operating should the make-up water assembly fail to prevent the pumps from running dry and burning up the mechanical seals. Numerous options are available.

^Go to top#Glossary

#Get product literature for BVC
#Get product literature for BVMC
SHVC / SHVM Vacuum Pumps

SHVC / SHVM Steel Horizontal Vacuum and Condensate unit with independent air and water pumps. Multi-jet design proven effective and reliable for removing air and lifting hot condensate in the return system. A standard heavy gauge black steel receiver from 3/16" to 3/8" thick provided for years of services. Receiver is divided into two compartments: one side is used for collecting hot condensate and the other side is the vacuum chamber. Standard unit designed for applications with system capacities ranging up from 1,000 square feet EDR; air pumps range up from 6 cubic feet per minute (cfm) at 5½" HG at 160°F. Unit completely packaged, including electrical controls.

Units are available in either simplex or duplex configuration with either 1750 RPM or 3500 RPM motors in either single or three phase. Pumps are flange mounted to the receiver and equipped with industry standard motors. Pumps bronze-fitted with removable bronze wearing ring and with mechanical seals rated for temperatures up to 250°F. Higher temperature seals and special faces available upon request.

Air and water pumps can be sized separate for customized applications that standard unit configurations can not meet.

Type SHVM is the boiler feed unit version of the SHVC. An electrical solenoid make-up water valve with float switch control is standard. A low water cut-off switch is furnished to prevent pumps from operating should the make-up water assembly fail to prevent the pumps from running dry and burning up the mechanical seals. Numerous options are available.

^Go to top#Glossary

#Get product literature for SHVC
#Get product literature for SHVM
BV Vacuum Pump

BV Big Vacuum producing unit for clinical (such as hospitals and laboratories) and industrial processes. Mufflers or silencers are not required because design is quieter than other types of vacuum pumps.

Multi-jet design proven effective and reliable for removing air and for lifting hot condensate in the return system. The vacuum tank (or hurling chamber) is either heavy gauge, black steel or cast iron depending upon sizing. Standard unit designed for applications with system capacities ranging up from 1,000 square feet EDR; air pumps range up from 5.8 cubic feet per minute (cfm) at 5½" HG at 160°F. Unit completely packaged, including electrical controls.

Units are available in either simplex or duplex configuration with either 1750 RPM or 3500 RPM motors in either single or three phase. Pumps are flange mounted to the receiver and equipped with industry standard motors. Pumps bronze-fitted with removable bronze wearing ring and with mechanical seals rated for temperatures up to 250°F. Higher temperature seals and special faces available upon request.

^Go to top#Glossary

#Get product literature for BV
HomeFind a Shipco® RepresentativeContact UsLogin to Shipco®Site Map
Copyright © 2008 Shippensburg Pump Co., Inc. All rights reserved. Legal Disclaimer and Privacy Policy.
There were 43 visitors in the last hour. 689110 since December 2003. Best viewed at 1024×768 screen display.